Occasion AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 8563E #9014804 à vendre en France

ID: 9014804
Spectrum analyzer Model number: 8565e Options: 006, 007, 008, 8ze Option description: Opt. 006: 30 hz to freq. Coverage Opt. 007: digitized fast time-domain sweeps Opt. 008: signal identification Key features: Continuous 30 hz to 26.5 ghz sweeps Resolution bandwidths of 1 hz to 100 hz digitally implemented for measurement speed Precision timebase and 1 hz counter resolution Adjacent channel power, channel power, carrier power and grated video measurements standard Mil-t-28800 rugged Frequency specifications: Frequency range (internal mixing): 9 khz to 26.5 ghz; 30 hz to 26.5 ghz (option 006) Frequency range (external mixing): 18 ghz to 325 ghz in 12-wave guide bands Frequency reference accuracy: Temperature stability: ±1 x 10-6 Aging (per year): ±1 x 10-7 Setability: ±1 x 10-8 Warmup (nominal): 5 minute ±1 x 10-7; 15 minute ±1 x 10 -8 Frequency readout accuracy (n = l0 harmonic): Span > 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy + 5% x span + 15% x rbw + 10 hz) Span < or = to 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy +1% x span +15% x rbw + 10 hz) Marker count accuracy (s/n > or = to 25 db): ± (marker freq. X freq. Ref. Accuracy + 2 hz x n + 1 lsd) Counter resolution: selectable from 1 hz to 1 mhz Frequency span: Range: 0 hz, 100 hz to maximum frequency Sweep time: Range: Span = 0 hz: 50 µs to 6,000 s Span > or = to 100 hz: 50 ms to 100 ks Accuracy: Sweep time > 30 ms: ±1% digital Sweep time < 30 ms: ±10% analog; ±0.1% digital (option 007) Sweep trigger: delayed, free run, single, line, video, external Resolution bandwidth: Range (-3 db): 1 hz to 1 mhz in a 1, 3, 10 sequence and 2 mhz Accuracy: 1 hz to 300 khz: ±10% 1 mhz: ± 25% 2 mhz: +50%, -25% Selectivity (-60 db/-3 db): Rbw > or = to 300 hz: < 15:1 Rbw < or = to 100 hz: < 5:1 Video bandwidth range: 1 hz to 3 mhz in a 1, 3, 10 sequence Noise sidebands (center frequency < or = to 1 ghz): 100 hz offset: < -18 dbc/hz 1 khz offset: < -97 dbc/hz 10 khz offset: < -113 dbc/hz 100 khz offset: < -117 dbc/hz Residual fm (zero span): < 1 hz p-p in 20 ms; < 0.25 hz p-p in 20 ms (nominal) Amplitude specifications: Range: displayed average noise level to +30 dbm Maximum safe input level: Average continuous power: +30 dbm (1w, input atten. > or = to 10 db) Peak pulse power (< 10 µs pulse width and < 1% duty cycle): +50 dbm (100 w, input atten. > or = to 30 db) Dc volts: < ±0.2 v (dc-coupled) 1 db gain compression: 10 mhz to 2.9 ghz: mixer level < or = to -5 dbm 2.9 ghz to 6.5 ghz: mixer level < or = to 0 dbm > 6.5 ghz: < or = to -3 dbm Displayed average noise level (0 db input atten., 1 hz rbw1): 30 hz frequency: -90 dbm 1 khz frequency: -105 dbm 10 khz frequency: -120 dbm 100 khz frequency: -120 dbm 1 to 10 mhz frequency: -140 dbm 10 mhz to 2.9 ghz frequency: -149 dbm 2.9 to 6.5 ghz frequency: -148 dbm 6.5 to 13.2 ghz frequency: -145 dbm 13.2 to 22.0 ghz frequency: -149 dbm 22.0 to 26.5 ghz frequency: -139 dbm Notes: 10 hz rbw (min. Rbw with option 103) add 10 db to noise floor Hp 8561e only Hp 8565e only Hp 8563e/64e/65e only Hp 8563e only Hp 8564e/65e only Except hp 8561e For hp 8561e: -145 dbm Toi reference to single tone Residual responses (>200 khz, n=1): <-90 dbm Display: Viewing area: approx. 7 cm (v) x 9 cm (h) Scale calibration: 10 x 10 divisions Log scale: 10, 5, 2, 1 db per division Linear scale: 10% of ref. Level per division Display scale fidelity: Log: ±0.1 db/db to a maximum of ±0.85 db, 0 to -90 db; maximum of ±1.5 db, 0 to -100 db (rbw < or = to 100 hz) Linear: ±3% of reference level Reference level range: log = -120 to +30 dbm in 0.1 db steps; linear = 2.2 µv to 7.07 v in 1% steps Frequency response, relative (10 db input attenuation): Frequency: 100 mhz to 2.0 ghz: ±1.0 db 30 hz to 2.9 ghz: ±1.25 db 2.9 ghz to 6.5 ghz: ±1.5 db 6.5 ghz to 13.2 ghz: ±2.2 db 13.2 ghz to 22.0 ghz: ±2.5 db 22.0 ghz to 26.5 ghz: ±3.3 db Calibrator output: 300 mhz x (1 ±freq. Ref. Acc'y), -10 dbm: < ±0.3 db Input attenuator: Range: 0 to 70 db in 10 db steps Switching uncertainty (ref. To 10 db, 30 hz to 2.9 ghz): < ±0.6 db/10 db step, ±1.8 db max. Repeatability: ±0.1 db (nominal) If gain uncertainty (10 db atten., 0 to -80 dbm ref. Level): < ±1 db Resolution bandwidth switching uncertainty: < ±0.5 db Pulse digitization uncertainty (pulse response mode, prf > or = to 720/sweep time, rbw < or = to 1 mhz): < 1.25 db pk-pk (log); 4% of reference level pk-pk (linear) Accuracy (from gate trigger input to pos. Edge of gate output): < ±1 µs Gate length: Range: 1 µs to 65.535 µs Resolution: 1 µs Accuracy (from pos. Edge to neg. Edge of gate output): < ±1 µs Delayed sweep specifications: Trigger modes: free run, line, external, video Range: 2 µs to 65.535 µs, option 007, sweeptime < 30 µs; -9.9 µs to +65.535 µs; sweeptime > or = to 30 µs, +2 µs to 65.535 µs Resolution: 1 µs Accuracy: ±1 µs Demodulation (spectrum) specifications: Modulation type: am and fm Audio output: speaker and phone jack with volume control Inputs and outputs (all values nominal) specifications: Front panel connectors: Rf input (50 ω): type-n female Vswr (> or = to 10 db atten.): < 1.5:1 below 2.9 ghz; < 2.3:1 > or = to 2.9 ghz Lo emission level (average with 10 db atten): < - 80 dbm Second if input (sma female, 50 ω): Frequency: 310.7 mhzfull screen level: -30 dbm Gain compression: -20 dbm First lo output (sma female, 50 ω): Frequency: 3.0 to 6.8107 ghz Amplitude: +16.5 dbm ±2 db Cal output: bnc female, 50 ω Probe power: +15 vdc, -12.6 vdc, and gnd (150 ma maximum each) Rear panel connectors: 10 mhz reference in/out (shared bnc female, 50 ω): Output frequency accuracy: 10 mhz ±(10 x mhz freq. Ref. Acc'y) Output amplitude: 0 dbm Input amplitude: -2 to +10 dbm Video output (bnc, 50 ω): Amplitude (rbw > or = to 300 hz): 0 to +1 v full scale Lo sweep i fav output (shared bnc female, 2 kω): Amplitude (lo sweep): 0 to 10 v, no load Blanking/gate output: shared bnc female, 50 ω, ttl output External/gate trigger input (shared bnc female, > 10 kω): settable to high ttl or low ttl Hp-ib: ieee-488 bus connector Interface functions: sh1, ah1, t6, l4, sr1, rl1, pp0, dc1, dt0, c1, c28, e1 General specifications: Environmental: Military specs: per mil-t-28800 Calibration interval: two years Warmup time: 5 minutes in ambient conditions Temperature: -10°c to +55°c (operating); -51° to +71°c (non operating) Humidity: 95% @ 40°c for five days Rain resistance: drip-proof at 16 liters/hour/sq. Ft. Altitude: 15,000 ft. (operating); 50,000 ft. (non operating) Pulse shock (half sine): 30 g for 11 ms duration Transit drop: 8-inch drop on six faces and eight corners Electromagnetic compatibility: conducted and radiated interference in compliance with cispr pub. 11 (1990). Meets mil-std-461c, part 4, with certain exceptions. Power requirements: 115 vac operation: 90 to 140 v rms, 3.2 a rms max., 47 to 440 hz 230 vac operation: 180 to 250 v rms, 1.8 a rms max., 47 to 66 hz Maximum power dissipation: 180 w Audible noise (nominal): < 5.0 bels power at room temp. (iso dp7779) Size (w/o handle, feet, cover): 337 mm w x 187 mm h x 460 mm d (13 1/4" x 7 3/8" x 18 1/8") Weight (carrying, nominal): 20 kg (44 lb).
AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E est un puissant équipement de test et de mesure électronique conçu pour répondre aux exigences des ingénieurs de conception et de fabrication. Il dispose d'une combinaison haute définition d'un analyseur de spectre et d'un analyseur de réseau en un seul instrument, permettant une analyse précise et un dépannage des circuits analogiques, numériques et RF. L'écran HD de 15,6 pouces de HP 8563E fournit une clarté précise et facilite le travail avec les applications de test et de mesure couramment utilisées. AGILENT 8563E est idéal pour les utilisateurs nécessitant une large gamme de capacités à partir d'un seul instrument. Il dispose d'une gamme de fréquences standard de 10 Hz à 3,6 GHz et est capable de mesurer une large gamme de paramètres, y compris les paramètres de courant continu (DC), la réponse en fréquence et les signaux parasites. KEYSIGHT 8563E est également équipé de puissantes capacités d'analyse telles que la figure de bruit, l'analyse harmonique, la perte de retour et les mesures d'impédance. Cela en fait un outil polyvalent pour des applications telles que les tests EMC, optiques, audio et vidéo. HEWLETT-PACKARD 8563E a une vitesse de balayage maximale de 10 ms, lui donnant la vitesse et la précision nécessaires pour la plupart des applications. Il comprend également une variété de fonctionnalités utiles pour un fonctionnement efficace, comme un affichage multilingue, ainsi qu'un ensemble intégré de résolution d'équations et de mathématiques. En outre, 8563E est équipé d'une série complète de tests automatisés pour vérifier rapidement le fonctionnement du dispositif par rapport aux limites spécifiées dans les essais de production. Cela permet aux utilisateurs de gagner du temps et de rationaliser le processus de test. AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E est conçu pour être facilement intégré dans les systèmes de test automatisés et les lignes de production, et il est compatible avec le logiciel LabView. HP 8563E est un équipement d'essai et de mesure fiable et robuste. Il fonctionne sur une seule alimentation en courant continu + 5V et rencontre la plupart des MIL-STD en blindage et décharge électrostatique. En outre, il répond aux normes UL et CE requises pour la sécurité, la compatibilité électromagnétique et la radioprotection radiofréquence. AGILENT 8563E est une solution de test et de mesure électronique puissante et fiable pour les équipes de conception, de développement et de fabrication. Son affichage HD de 15,6 ", ses capacités d'analyse polyvalentes, ses tests automatisés et sa facilité d'intégration en font un excellent choix pour une variété d'applications.
Il n'y a pas encore de critiques