Occasion AIST-NT CombiScope 1000 #9208611 à vendre en France

Fabricant
AIST-NT
Modèle
CombiScope 1000
ID: 9208611
Scanning probe microscope AFM Laser: 1300 nm TOKYO INSTRUMENTS Nanofinder 30 Raman optical system: Light for TERS Digital controller Measuring modes: Contact AFM in air Semicontact AFM in air Non-contact AFM Phase imaging Lateral force microscopy (LFM) Force modulation Magnetic force microscopy (MFM) Kelvin Probe (Surface potential microscopy) Capacitance and electric force microscopy (EFM) Force curve measurements Piezo response force microscopy Nanolithography Nanomanipulation Scanner: Scanning range: 100um x 100um x 20um (+/-10%) Scanning range: 200um x 200um x 20um (+/-10%) Scanning type: Sample XY Non-linearity: 0.05% Z Non-linearity: 0.05% Noise level: 0.1nm RMS in XY dimension in 100Hz bandwidth With capacitance sensors on 0.02nm RMS in XY dimension in 100Hz bandwidth With capacitance sensors off <0.1nm RMS Z capacitance sensor in 1000Hz bandwidth Digital closed loop control: X, Y, Z Axes Active elimination of XY phase lag Overshooting and ringing results in fast scanning Without any dynamic image distortion Base: Manual sample positioning: Range: 25 x 25 mm Positioning resolution: 1um Motorized SPM measuring head positioning: 1.6 x 1.6mm Positioning resolution: 1um Motorized approach: 1.3 mm Sample holder for standard slides and cover glasses Sample holders: Maximum sample size: 50.8 x 50.8 mm Height: 5 mm With capability measuring area: 25 x 25 mm in any quadrant of 50.8 x 50.8 mm area / In center of sample Maximum sample size: Upto 100 mm width Length: More than 100 mm Height: Up to 15 mm With capability to measuring area: 25 x 25 mm in any part of center cross With width: 25 mm AFM Head HE001: Laser wavelength: 1300nm No registration laser influence on biological sample No registration laser influence on photovoltaic measurements Registration system noise: <0.03nm Fully motorized: (4) Stepper motors for cantilever and photodiode automated alignment Free access to the probe for additional external manipulators and probes Top and side simultaneous optical access With planapochromat objectives: (10x, NA=0.28 and 20x, NA=0.42) AFM Head HE002: Laser wavelength: 1300nm No registration laser influence on biological sample No registration laser influence on photovoltaic measurements Registration system noise: <0.1nm Fully motorized: (4) Stepper motors for cantilever and photodiode automated alignment Free access to the probe for additional external manipulators and probes Top and side simultaneous optical access With planapochromat objectives (100x, NA=0.7 and 10x, NA=0.28) Optical access: With AFM head HE001: Capability to use simultaneously top and side planapochromat objectives (10x, NA=0.28 and 20x, NA=0.42) Field of view: From 900m - 140m Optical resolution: 1m Bottom optical access with dry and immersion objective With AFM head HE002: Capability to use simultaneously top and side planapochromat objectives (100x, NA=0.7 and 10x, NA=0.28) Field of view: From 100m - 50m Optical resolution: 0.4m Maximum side planapochromat objectives: 20x, NA=0.42 Bottom optical access With dry and immersion objective Compatibility with inverted optical microscopes No interference With optical imaging due to infrared laser Capability to install on: NIKON: Ti-E, Ti-U, Ti-S, TE2000; OLYMPUS: IX-71, IX-81 Phase contrast, DIC and fluorescent techniques With native optical condenser Upgradeability to OmegaScope for spectroscopic and TERS operation Numerical aperture: Up to 0.1 Magnification: 19" Monitor With 1/3" CCD: From 85x - 1050x Horizontal field of view: From 4.5 - 0.37 mm Stand and coarse / Fine focusing unit Capability to use planapochromat objectives: 10x, NA=0.28 20x, NA=0.42 100x, NA=0.7 (Depends on AFM head) Capability to use M plan Apo objective: 10x, NA = 0.28 Magnification: 19" Monitor With 1/3" CCD: 400x - 5300x Horizontal field of view: From 0.96 - 0.07 mm Resolution: Up to 1 um Vibration isolation: Isolation: Dynamic 0.7Hz - 1kHz, beyond 1kHz Size: 400 x 450 x 75mm Controller electronics: Modular fully digital expandable controller DSP 190 MHz USB 2.0 Interface High speed 500 kHz 18-bit ADC 20 Channels 5 MHz frequency range registration system (2) Lock-in amplifiers Frequency range: 5 MHz (6) Digital Generators: 32–bit Frequency range: 5 MHz Resolution: 0.01 Hz HV Amplifiers: -5 +120V, 0.4 ppm HV noise AC, DC Bias voltage: -10, +10V Frequency range: 2 MHz (7) Stepper motors control Digital inputs / Outputs for integration With external equipment Analog input / Outputs for integration With external equipment Computer: High performance computer Intel Core 2 Duo RAM: 1GB 500GB HDD DVD R/W (2) 19" LCD monitors S-video capture card Operation system: Windows XP.
AIST-NT CombiScope 1000 est un microscope de recherche avancée conçu pour la biotechnologie et les applications de la science des matériaux. Il utilise l'optique avancée et les technologies d'imagerie intégrées pour fournir aux utilisateurs des capacités d'imagerie haute résolution. CombiScope 1000 présente une variété de caractéristiques, y compris des objectifs à haute résolution qui permettent une résolution maximale de 0,7 µm dans le champ de vision. Il est également équipé d'une conception optique corrigée qui supporte à la fois la microscopie lumineuse réfléchie et fluorescente. De plus, la conception mécanique avancée du microscope permet aux chercheurs d'effectuer une imagerie à grande vitesse, ainsi qu'un positionnement précis des échantillons en détail. Le microscope est capable d'imagerie dans le spectre visible, ultraviolet et proche infrarouge, et il peut être facilement amélioré avec de nouvelles capacités telles que les caméras, les sources lumineuses et les objectifs. Il est également compatible avec une gamme d'applications logicielles qui facilitent l'analyse d'images. L'AIST-NT CombiScope 1000 est équipé de technologies d'imagerie avancées, et ses fonctionnalités automatisées permettent un fonctionnement facile. Il est également capable de produire des images très précises avec des détails précis et la précision de la couleur. Il utilise un processeur de signal numérique pour ajuster automatiquement les éléments afin d'optimiser les images. En plus de ses capacités d'imagerie avancées, CombiScope 1000 est compatible avec une gamme de porte-échantillons et d'accessoires pour une variété de tâches. Cela comprend le système de retenue d'échantillons illustré à vacum (VIHSS), qui est utilisé pour fournir une chambre sécurisée et une perturbation minimale des échantillons pour l'imagerie d'échantillons fragiles. Il est également livré avec un PC intégré qui est utilisé pour contrôler le microscope, ainsi que d'analyser et stocker des images et des données. Dans l'ensemble, AIST-NT CombiScope 1000 est un microscope de recherche avancée qui fournit aux chercheurs une vaste gamme de fonctionnalités et de capacités pour l'imagerie haute résolution. Ses fonctions automatisées, son optique avancée et sa compatibilité avec une gamme de logiciels et d'accessoires le rendent idéal pour une variété d'applications en biotechnologie et en sciences des matériaux.
Il n'y a pas encore de critiques